| Defines what a Pulmonary Mini-Lab can do |  |  |  | The most powerful, the most simple | | | | | Unique in the world All in one | | Spirometer with 6000 test memory. Oximeter with 1000 hours recording. Stand alone or PC online operation. Graphic display with user friendly icons. Patient identification by name or ID code. Bluetooth® connection to printer or mobile phone. USB, RS232 and wireless acoustic modem. Upgradeable internal software via internet. | | | | | | Spirometry features | | FVC, VC, IVC, MVV, PRE-POST BD. Automatically records the best 3 trials. Internal temperature sensor for automatic BTPS. Advanced spirometry test interpretation. Lung age estimation.
| | | | | SpO2 module (option) | | Sleep disorder detection with events recording. Six minute walk test with automatic alarm for rest, walk and recovery. Parameters directly shown on the display (min, max, mean SpO2 and Pulse Rate, Δ Index, T90, T89, T88, T5, ODI, NOD, Desaturation Area etc.). Its innovative functions make it the most unique oximeter on the market | | | | | | Large display | | All results are shown directly on the display | | | | | winspiroPRO PC software  | | Spirometry program Flow/Volume and Volume/time curves. PRE-POST bronchodilator comparison. FEV1 dose-response curve. Exclusive paediatric incentive system. Advanced spirometry test interpretation. Several sets of predicted values. Integration with Electronic Medical Record. Data and graphs export also via e-mail. Oximetry program PC online with SpO2 and Pulse Rate trend. Desaturation events analysis. Possibility to modify the registered data (start/end walk test phase, artefacts, etc.). One of the most distinctive elements of the spirobank II is the "specialised and detailed" printout in colour, which is easy to read and facilitates the diagnostic interpretation | | | | | Available options  | | Adult reusable SpO2 finger probe Adult disposable SpO2 finger probe Paediatric reusable SpO2 finger probe Neonatal reusable SpO2 probe Neonatal disposable SpO2 probe SpO2 extension cable RS232 cable for PC | | | | | | Two different flowmeters available | | FlowMir disposable turbine for single patient use High accuracy. Easy to replace. Very low cost. Designed for use with MIR spirometers. FlowMIR is factory calibrated. Available in box of 100 pieces. No maintenance – No filter – No problem. Hygiene 100% guaranteed by single packaging. |  | | Reusable turbine for long term operation High accuracy Long term stability Easy to clean or sterilize | | | | | Standard price includes | | spirobank II base unit USB cable Carrying case Plastic noseclip 4 AAA alkaline batteries winspiroPRO software CD | | | | | Spirometer Technical specifications | | | spirobank II base unit | | Measured values: | FVC, FEV1, FEV1/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25-75%, FET, Vext, FIVC, FIV1, FIV1/FIVC%, PIF, *FVC, *FEV1, *PEF, VC, IVC, IC, ERV, FEV1/VC%, VT, VE, Rf, ti, te, ti/t-tot, VT/ti, MVV (* = Best value). | | Temperature sensor: | semiconductor (0-45°C) | | Flow sensor: | bi-directional digital turbine | | Flow range: | ± 16 L/s | | Volume accuracy: | ± 3% or 50 mL, whichever is greater | | Flow accuracy: | ± 5% or 200 mL/s, whichever is greater | | Dynamic resistance at 12 L/s: | <0.5 cmH2O/L/s | | Display: | graphic LCD - FSTN, 128x64 pixel | | Keyboard: | membrane, 6 Keys | | Communication port: | USB, Bluetooth®, and RS232 | | Bluetooth profile: | service discovery application, generic access, serial port | | Power Supply: | 4 x 1.5 V, AAA battery. On line mode USB PC connected Spirobank II is supplied directly by the PC | | Dimension: | 60 x 145 x 30 mm | | Weight: | 180 grams (battery included) | | | | | | Option: Digital Oximeter | | SpO2 range: | 0-99% | | SpO2 accuracy: | ± 2% between 70-99% SpO2 | | Pulse Rate range: | 30-254 BPM | | Pulse Rate accuracy: | ± 2 BPM or 2%, whichever is greater | | Measured parameters: | | Basic: SpO2 [Baseline, Min, Max, Mean], Pulse Rate [Baseline, Min, Max, Mean], T90 [SpO2<90%], T89 [SpO2<89%], T88 [SpO25%], Δ Index [12s], SpO2 Events, Pulse Rate Events [Bradycardia, Tachycardia] | | 6 Minute Walk Test: TΔ2 [SpO2≥2%], TΔ4 [ΔSpO2≥4%], Recording time, Time [Rest, Walking, Recovery], Walked Distance, Predicted Distance [Min, Standard], Desaturation Area/Distance, Borg Dyspnea [Baseline, End, Change], Borg Fatigue [Baseline, End, Change] | | Sleep Test: Desaturatin Events, Desaturation Index (ODI), Desaturation [Value, Duration, Nadir], ΔSpO2 [Min Drop, Max Drop], Pulse Variations, Pulse Rate Index, NOD 89 [SpO25 min], NOD 4 [SpO2 Baseline-4%; >5 min], NOD 90 [SpO2<90%; Nadir 5 min] | | | | | | PC system requirements | | Microsoft Windows 98 (Second Edition), NT 4.0, 2000, Me, XP Minimum CPU clock 300 Mhz Minimum RAM: 64 MB (128 MB on Windows NT) Recommended RAM: 128 MB USB socket available (RS 232 option) Screen resolution 1024 x 768 Hard disk space required: 160MB | | | | | | | Quality spirometry | |  | FDA | ATS-ERS | ISO | ISO | | 0476 | Approved | Standards | 9001-2000 | 13485 | |
|